W505
Suitable for customers who need a compact controller with SVC, V/F and torque control, built-in PID and configurable I/O.
product details
Product Overview
W505 is a sensorless vector control controller for AC motor drive applications. It provides stable frequency output, flexible control sources and complete motor protection for industrial equipment.
The series is suitable for customers who need a compact controller with SVC, V/F and torque control, built-in PID and configurable I/O.
Key Selling Points
- Supports SVC, V/F and torque control.
- Output frequency range: 0Hz to 600Hz.
- Built-in PID control and up to 16-step simple PLC speed control.
- Non-stop function during instantaneous power cut and speed trace start for rotating motors.
- Automatic voltage regulation keeps output voltage stable under input fluctuation.
- Protection functions include over-current, over-voltage, under-voltage, overheat, phase failure and overload.
Core Parameters
| Item | Details |
| Input voltage | 220V / 380V AC, +/-15% |
| Input frequency | 47Hz to 63Hz |
| Output voltage | 0V to rated input voltage |
| Output frequency | 0Hz to 600Hz |
| Control modes | Sensorless Vector Control (SVC), V/F Control, Torque Control |
| Overload capacity | G type: 150% rated current for 60s, 180% for 3s; P type: 120% rated current for 60s, 135% for 3s |
| Starting torque | G type: 0.5Hz / 150% (SVC); P type: 0.5Hz / 100% |
| Speed regulation | 1:100 (SVC), speed accuracy up to +/-0.5% of maximum speed |
| Carrier frequency | 0.5kHz to 16.0kHz |
| Working environment | -10C to 40C; less than 95% RH without condensation; altitude below 1000m without derating |
Model Coverage
| Model / Voltage Class | Power Range | Notes |
| 1AC 220V input | 0.75kW to 2.2kW | 3PH 0-220V output |
| 3AC 220V input | 0.75kW to 55kW | 3PH 0-220V output |
| 3AC 380V input | 0.75kW to 220kW | 3PH 0-380V output |
Interface and Control
- Six programmable digital input terminals.
- AI1 and AI2 support 0-10V voltage input or 4-20mA current input.
- Two relay output terminals.
- AO1 supports 0-20mA current output or 0-10V voltage output; AO2 supports 0-20mA current output.
- Serial communication is available for external control and monitoring.
Application Scenarios
- Industrial motor speed control.
- Fans, pumps and mechanical equipment requiring adjustable frequency drive.
- Systems needing PID control, multi-step speed operation or remote communication.
Installation and Use Notes
- Select the model according to the motor rated power and rated current.
- Use proper grounding and avoid incorrect wiring at the output terminals.
- Do not start or stop the controller by frequently switching the input contactor.
- Install in a dry, clean and well-ventilated location away from corrosive gas, oil mist and strong vibration.
FAQs
What is the W505 used for? ▶
W505 adjusts motor speed to suit the work being done. It can be used with suitable motor-driven equipment, including pumps, where changing speed is useful.
How should I select a W505 controller? ▶
Choose a model using the motor nameplate and the power supply available on site. The controller and motor ratings must match; have the chosen combination checked before installation.
Can W505 work with an existing pump motor? ▶
W505 is intended for ordinary three-phase motors. Whether an existing pump is suitable depends on its motor data, power supply, pump load, and the selected W505 model.
Is W505 available for different supply arrangements? ▶
The series includes 220 V and 380 V versions. Only specified lower-power 220 V models are listed with single-phase input, so do not assume that any model or motor will suit a domestic supply.
Can W505 use preset operating speeds? ▶
Yes. You can save different running speeds and switch between them as needed. This is useful when the same equipment does different jobs.
Where do I start or adjust a W505? ▶
The controller has a local keypad for normal setup and use. External controls can also be set up for an installation; have electrical connections and settings completed by a trained installer.
Will running slowly affect the motor? ▶
It can. A standard motor may receive less cooling at low speed, so the intended speed range and cooling conditions should be checked when selecting the system.
What should I do when W505 reports a fault? ▶
Do not repeatedly reset the controller without finding the cause. Use the fault information to check the power supply, motor, pump load, and wiring, then seek service help when needed.
Contact Us Immediately